Home

Product >> Rolling Stock Cable

Rolling Stock Cables

FIREROL FRL-MW-3S/FRL-MW-6S

Rolling Stock Cables

  A. Conductor            B. Insulation             C. Sheath

Application

-Used as power and control cable for protected installations inside and outside of rail and transport vehicles, where handling and installation cost are an important factor.

-Used in control, auxillary and main circuit wiring such as cable harnesses, switchboards and control panels, driver desks etc.

Construction

Conductor
Flexible tinned annealed copper wires, stranded as per HD 383 (IEC 60228) class 5

Insulation
LSZH elastomeric compound as defined in EN 50264-1 (EI 106 to EI 109)

Sheath
LSZH elastomeric compound as defined in EN 50264-1 (EM 101 to EM 104)

Electrical & Mechanical Properties

Nominal Voltage 1.8/3 kV or 3.6/6 kV
Maximum Conductor Temperature +90 deg (fixed installation)
Minimum Permissible Ambient Temperature -25/-40 deg (fixed installation)
Bending Radius 3 x Overall Diameter (D<12mm);
  4 x Overall Diameter (D>12mm)

Chemical & Environmental Properties

EN 60684-2 No fluorine
EN 50305; EN 60811-2-1 Resistance to oil & fuel
EN 50305 Resistance to ozone

Fire Performance for rolling stock application

EN 50306-2 Hazard levels HL1, HL2/HL3, HL4
DIN 5510-2 Protection level 1/2/3/4
BS 6853 Interior use 1a, 1b, II; Exterior use 1a, 1b, II
NF F 16-101 FO

Fire Performance in general

EN 50265-2-1; IEC 60332-1; BS 4066-1 Vertical flame propogation for a single insulated wire or cable
EN 50266-2-4 + EN 50305; IEC 60332-3C; Fire propagation of bunched wires and cables;
VDE 0472 Teil 804; BS 4066-3; NFC 32070  
EN 50268-2; IEC 61034-2; VDE 0472 Teil 816 Smoke density
EN 50267-2-1; IEC 60754-1; VDE 0472 Teil 815 Halogen Free
EN 50267-2-2/3; IEC 60754-2; VDE 0472 Teil 813 Corrosivity of gases (Acidity & Conductivity)
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 Toxicity index
NFF 16101; NFF 63808; BS6853 Smoke index

FRL-MW-3S 1.8/3 kV

NOMINALCROSS-SECTIONAL AREA(a)

CONDUCTOR DIAMETER (a)

MIN.
MEAN THICKNESS OF INSULATION

SHEATH NOMINAL THICKNESS MIN.

OVERALL DIAMETER MIN.

OVERALL DIAMETER MAX.

WEIGHT

COND
UCTOR RESIST
ANCEAT
+20°C

INSULATION RESISTANCE AT +20°C

INSULATION RESISTANCE AT +90°C

max

min

min

mm^2

mm

mm

mm

mm

mm

Kg/km

Ω/km

MΩ·km

MΩ·km

1.5

1.5

1.3

0.8

5.7

6.7

60

13.7

21.8

0.218

2.5

1.95

1.3

0.8

6.0

7.0

70

8.21

18.8

0.188

4

2.5

1.3

0.8

6.5

7.6

90

5.09

16.2

0.162

6

3.0

1.3

0.8

7.0

8.1

110

3.39

14.4

0.144

10
3.9
1.5
0.8
8.2
9.6
170
1.95
12.8
0.128
16
5.0
1.5
0.8
9.2
10.8
240
1.24
10.7
0.107
25
6.4
1.8
1.0
11.5
13.4
350
0.795
10.3
0.103
35
7.7
1.8
1.0
12.7
14.9
450
0.565
8.9
0.089
50
9.2
1.8
1.0
14.1
16.5
590
0.393
7.8
0.078
70
11.0
1.8
1.0
15.8
18.5
790
0.277
6.7
0.067
95
12.5
2.2
1.0
18.0
21.0
1050
0.210
6.5
0.065
120
14.2
2.2
1.0
19.6
22.9
1270
0.164
6.1
0.061
150
15.8
2.2
1.2
21.4
25.1
1590
0.132
5.8
0.058
185
17.5
2.4
1.2
23.4
27.4
1900
0.108
5.6
0.056
240
20.1
2.4
1.2
25.9
30.3
2490
0.0817
5.0
0.050
300
22.5
2.4
1.2
28.1
32.9
3010
0.0654
4.5
0.045
400
25.8
2.6
1.4
32.0
37.4
3980
0.0495
4.4
0.044

FRL-MW-6S 3.6/6KV

NOMINALCROSS-SECTIONAL AREA

CONDUCTOR DIAMETER (a)

MIN.
MEAN THICKNESS OF INSULATION

SHEATH NOMINAL THICK
NESS MIN.

OVERALL DIAMETER MIN.

OVERALL DIAMETER MAX.

WEIGHT

CONDUCTOR RESIST
ANCEAT +20°C

INSULATION RESISTANCE AT +20°C

INSULATION RESISTANCE AT +90°C

max

min

min

mm^2

mm

mm

mm

mm

mm

Kg/km

Ω/km

MΩ·km

MΩ·km

2.5

1.95

2.6

0.8

8.6

10.1

120

8.21

24.6

0.246

4

2.5

2.6

0.8

9.1

10.7

140

5.09

21.6

0.216

6

3.0

2.6

0.8

9.6

11.2

165

3.39

19.5

0.195

10

3.9

2.6

0.8

10.4

12.2

220

1.95

16.7

0.167

16

5.0

2.6

0.8

11.5

13.4

290

1.24

14.2

0.142

25

6.4

2.9

1.0

13.7

16.1

430

0.795

13.1

0.131

35

7.7

2.9

1.0

14.9

17.5

540

0.565

11.6

0.116

50

9.2

2.9

1.0

16.4

19.1

670

0.393

10.2

0.102

70

11.0

2.9

1.0

18.0

21.1

880

0.277

8.9

0.089

95

12.5

2.9

1.0

19.5

22.8

1100

0.210

8.0

0.080

120

14.2

2.9

1.2

21.4

25.1

1380

0.164

7.5

0.075

150

15.8

2.9

1.2

22.9

26.8

1660

0.132

6.9

0.069

185

17.5

3.2

1.2

25.1

29.4

2010

0.108

6.7

0.067

240

20.1

3.4

1.4

28.3

33.1

2670

0.0817

6.4

0.064

300

22.5

3.4

1.4

30.6

35.8

3170

0.0654

5.9

0.059

400

25.8

3.4

1.4

33.7

39.4

4150

0.0495

5.2

0.052

(a)= For information,indicative only